Cooling Water Supply Pipe Leaks
→ Resources → Case Studies
Cooling Water Supply Pipe Leaks
→ Resources → Case Studies
Market
Marine
Challenge
The challenge was to repair leaks in the cooling water supply pipe.



Engineered Solution
The solution utilized the Marine HydraWrap® Structural Composite Repair System.
Scope
The cooling water system on a vessel experienced leaks and deterioration of the pipe wall. These leaks and deterioration were noticed primarily in the pipe fittings located immediately downstream of the supply pumps.

Solution
Temporary patches and repair bands were implemented in the past to reduce the leaking. Still searching for a better repair, the client was introduced to HydraTech’s ABS Design Approved Marine HydraWrap®, and they requested the repairs be made to several areas of the system where leaks had developed. The areas of the CuNiFe piping were prepared and cleaned using hand and power tools to provide a clean surface and remove any foreign material. The HydraWrap® carbon fiber system was then applied.